    ItemDescription&Characteristics
    Product StandardIEC60245-4:2004; GB/T5013.4-2008
    Product Namerubber sheath H07RN-F cable
    Product ModelH07RN-F ; Model No. in China;YCW
    Rated Voltage(U0/U)450/750V
    Insulation MaterialRubber compound
    Sheath MaterialRubber compound(CPE)
    Conductor MaterialCopper wire
    Operating temperature rangeNot exceed 60°C
    Cross Sectional Area1.5mm2- 400mm2
    Cores1core,2core;3core;4core;5core;6core;3+1core
    Trademark Hyand Cable
    Supplier′s Nature Factory
    Core No.xNominal sectional area(mm2)Pcs./Wire dia.(mm)Insulation thickness(mm)Sheath thickness(mm)Average outer dia.(mm)Reference weight kg/kmMax DC resistance of conductor at 20℃ Ω/km
    MinMax
    1x1.530/0.250.81.45.77.17013.3
    1x2.549/0.250.91.46..37.9907.98
    1x456/0.301.01.57.29.01194.95
    1x684/0.301.01.67.99.81603.30
    1x1084/0.401.21.89.511.92371.91
    1x16126/0.401.21.910.813.43141.21
    1x25196/0.401.42.012.715.84520.780
    1x35276/0.401.42.214.317.95870.554
    1x50396/0.401.62.416.520.68050.386
    1x70360/0.501.62.618.623.311160.272
    1x95475/0.501.82.820.826.014400.206
    1x120608/0.501.83.022.828.617250.161
    1x150756/0.502.03.225.231.421150.129
    1x185925/0.502.23.427.634.426750.106
    1x2401221/0.502.43.530.638.334150.0801
    1x3001525/0.502.63.633.541.942180.0641
    1x4002013/0.502.83.837.446.854240.0495
    2x132/0.200.81.37.710.010819.5
    2x1.530/0.250.81.58.511.013413.3
    2x2.549/0.250.91.710.213.11977.98
    2x456/0.301.01.811.815.12504.95
    2x684/0.301.02.013.116.83583.30
    2x1084/0.401.23.117.722.66491.91
    2x16126/0.401.23.320.225.78021.21
    2x25196/0.401.43.624.330.711890.780
    2x16126/0.401.23.320.225.78021.21
    2x95475/0.501.85.040.251.033040.206
    3x132/0.200.81.48.310.713219.5
    3x1.530/0.250.81.69.211.918013.3
    3x2.549/0.300.91.810.914.02457.98
    3x456/0.301.01.912.916.23304.95
    3x684/0.301.02.114.118.04653.30
    3x1084/0.401.23.319.124.28251.91
    3x16126/0.401.23.521.827.611051.21
    3x25196/0.401.43.826.133.015880.780
    3x35276/0.401.44.129.337.122970.554
    3x50396/0.401.64.534.142.928050.386
    3x70360/0.501.64.838.448.336120.272
    3x95475/0.501.85.343.354.047310.206
    3x150756/.502.06.052.066.068540.129
    4x132/0.200.81.59.211.916819.5
    4x1.530/0.250.81.710.213.122513.3
    4x2.549/0.250.91.912.115.53087.98
    4x456/0.301.02.014.017.94084.95
    4x684/0.301.02.315.710.05963.30
    4x1084/0.401.23.420.926.58841.91
    4x16126/0.401.23.623.830.111971.21
    4x25196/0.401.44.128.936.620050.780
    4x35276/0.401.44.432.541.125430.554
    4x50396/0.401.64.837.747.535500.386
    4x70360/0.401.65.242.754.046900.272
    4x95475/0.501.85.948.461.061200.206
    4x120608/0.501.86.053.066.072800.161
    4x150756/0.502.06.558.073.090190.129
    5x132/0.200.81.610.213.120219.5
    5x1.530/0.250.81.811.214.426713.3
    5x2.549/0.250.92.013.317.03797.98
    5x456/0.301.02.215.619.95504.95
    5x684/0.301.02.517.522.27503.30
    5x1084/0.401.23.622.929.112751.91
    5x16126/0.401.43.926.433.316621.21
    5x25196/0.401.44.432.040.423800.780
    5x35280/0.401.44.5374227160.554
    we can design and customize as per your specific applications.More models please let us know.

       Withstand weather, oils/greases, mechanical and thermal stresses. Used as power cable for equipment in industry work such as boilers, heating plates, hand lamps, transportable motor etc. 

       Could be installed at medium mechanical stress in dry, damp and wet areas as well as in open air and in agriculture plants.Suitable for direct laying on components and mechanical parts of machines i.e. lifts and cranes.


    By roll,By wooden drum,According to your requires

Specification
ItemDescription&Characteristics
Product StandardIEC60245-4:2004; GB/T5013.4-2008
Product Namerubber sheath H07RN-F cable
Product ModelH07RN-F ; Model No. in China;YCW
Rated Voltage(U0/U)450/750V
Insulation MaterialRubber compound
Sheath MaterialRubber compound(CPE)
Conductor MaterialCopper wire
Operating temperature rangeNot exceed 60°C
Cross Sectional Area1.5mm2- 400mm2
Cores1core,2core;3core;4core;5core;6core;3+1core
Trademark Hyand Cable
Supplier′s Nature Factory
Core No.xNominal sectional area(mm2)Pcs./Wire dia.(mm)Insulation thickness(mm)Sheath thickness(mm)Average outer dia.(mm)Reference weight kg/kmMax DC resistance of conductor at 20℃ Ω/km
MinMax
1x1.530/0.250.81.45.77.17013.3
1x2.549/0.250.91.46..37.9907.98
1x456/0.301.01.57.29.01194.95
1x684/0.301.01.67.99.81603.30
1x1084/0.401.21.89.511.92371.91
1x16126/0.401.21.910.813.43141.21
1x25196/0.401.42.012.715.84520.780
1x35276/0.401.42.214.317.95870.554
1x50396/0.401.62.416.520.68050.386
1x70360/0.501.62.618.623.311160.272
1x95475/0.501.82.820.826.014400.206
1x120608/0.501.83.022.828.617250.161
1x150756/0.502.03.225.231.421150.129
1x185925/0.502.23.427.634.426750.106
1x2401221/0.502.43.530.638.334150.0801
1x3001525/0.502.63.633.541.942180.0641
1x4002013/0.502.83.837.446.854240.0495
2x132/0.200.81.37.710.010819.5
2x1.530/0.250.81.58.511.013413.3
2x2.549/0.250.91.710.213.11977.98
2x456/0.301.01.811.815.12504.95
2x684/0.301.02.013.116.83583.30
2x1084/0.401.23.117.722.66491.91
2x16126/0.401.23.320.225.78021.21
2x25196/0.401.43.624.330.711890.780
2x16126/0.401.23.320.225.78021.21
2x95475/0.501.85.040.251.033040.206
3x132/0.200.81.48.310.713219.5
3x1.530/0.250.81.69.211.918013.3
3x2.549/0.300.91.810.914.02457.98
3x456/0.301.01.912.916.23304.95
3x684/0.301.02.114.118.04653.30
3x1084/0.401.23.319.124.28251.91
3x16126/0.401.23.521.827.611051.21
3x25196/0.401.43.826.133.015880.780
3x35276/0.401.44.129.337.122970.554
3x50396/0.401.64.534.142.928050.386
3x70360/0.501.64.838.448.336120.272
3x95475/0.501.85.343.354.047310.206
3x150756/.502.06.052.066.068540.129
4x132/0.200.81.59.211.916819.5
4x1.530/0.250.81.710.213.122513.3
4x2.549/0.250.91.912.115.53087.98
4x456/0.301.02.014.017.94084.95
4x684/0.301.02.315.710.05963.30
4x1084/0.401.23.420.926.58841.91
4x16126/0.401.23.623.830.111971.21
4x25196/0.401.44.128.936.620050.780
4x35276/0.401.44.432.541.125430.554
4x50396/0.401.64.837.747.535500.386
4x70360/0.401.65.242.754.046900.272
4x95475/0.501.85.948.461.061200.206
4x120608/0.501.86.053.066.072800.161
4x150756/0.502.06.558.073.090190.129
5x132/0.200.81.610.213.120219.5
5x1.530/0.250.81.811.214.426713.3
5x2.549/0.250.92.013.317.03797.98
5x456/0.301.02.215.619.95504.95
5x684/0.301.02.517.522.27503.30
5x1084/0.401.23.622.929.112751.91
5x16126/0.401.43.926.433.316621.21
5x25196/0.401.44.432.040.423800.780
5x35280/0.401.44.5374227160.554
we can design and customize as per your specific applications.More models please let us know.
Application

   Withstand weather, oils/greases, mechanical and thermal stresses. Used as power cable for equipment in industry work such as boilers, heating plates, hand lamps, transportable motor etc. 

   Could be installed at medium mechanical stress in dry, damp and wet areas as well as in open air and in agriculture plants.Suitable for direct laying on components and mechanical parts of machines i.e. lifts and cranes.


Packing

By roll,By wooden drum,According to your requires