PV Cable
Home   >   Products   >   Mining Cables
Flexible rubber-sheathed coal cutter cable MCP-1.9/3.3kv

Flexible rubber-sheathed coal cutter cable MCP-1.9/3.3kv

Share
    ItemDescription& Characteristics
    Product NameFlexible rubber-sheathed coal cutter cable MCP-1.9/3.3kv
    Conductor TypePower core conductor
    Conductor materialCopper wire
    Insulation materialRubber compound
    Sheath materialRubber compound
    Working voltage1.9/3.3kv
    Permissible continuous working temperature of conductor90℃
    Sectional area of cable4mm2~185mm2
    Sheath color of cableblack
    Flame-retardant performance standardMT386
    The bending radius6 ×O.D.
    BrandHyandcable
    Supplier′s NatureManufacturer
    Core number×nominal sectional area of conductor(mm2)Nominal thickness(mm)O.D. Of cable(mm)Calculated weight of cable
    Power coreEarthing corePower core insulationExternal sheathMCP-1.9/3.3kvKg/km
    3x41x42.25.027.5~30.01300
    3x61x62.25.029.2-31.81580
    3x101x602.45..535.0-38.02100
    3x161x62.45..537.2--40.42480
    3x251x62.66.042.6-45.83200
    3x351x62.86.052.1-56.83990
    3x501x252.87.056.4-62.05160
    3x701x353.07.062.7-69.06530
    3x951x503.07.067.8-74.68000
    3x1201x503.07.067.0-68.08000
    3x1201x503.27.072.0-76.59000
    3x1501x703.27.078.0-83.011250
    3x1851x953.47.582.5-88.013200
    Note: the control core.number and sectional ares may be customized according to customers requirements

    Applicable for power connection of coal cutter and similar equipment with rated voltage up to and including 1.9/3.3kv

    We can according to customer requirement

Specification
ItemDescription& Characteristics
Product NameFlexible rubber-sheathed coal cutter cable MCP-1.9/3.3kv
Conductor TypePower core conductor
Conductor materialCopper wire
Insulation materialRubber compound
Sheath materialRubber compound
Working voltage1.9/3.3kv
Permissible continuous working temperature of conductor90℃
Sectional area of cable4mm2~185mm2
Sheath color of cableblack
Flame-retardant performance standardMT386
The bending radius6 ×O.D.
BrandHyandcable
Supplier′s NatureManufacturer
Core number×nominal sectional area of conductor(mm2)Nominal thickness(mm)O.D. Of cable(mm)Calculated weight of cable
Power coreEarthing corePower core insulationExternal sheathMCP-1.9/3.3kvKg/km
3x41x42.25.027.5~30.01300
3x61x62.25.029.2-31.81580
3x101x602.45..535.0-38.02100
3x161x62.45..537.2--40.42480
3x251x62.66.042.6-45.83200
3x351x62.86.052.1-56.83990
3x501x252.87.056.4-62.05160
3x701x353.07.062.7-69.06530
3x951x503.07.067.8-74.68000
3x1201x503.07.067.0-68.08000
3x1201x503.27.072.0-76.59000
3x1501x703.27.078.0-83.011250
3x1851x953.47.582.5-88.013200
Note: the control core.number and sectional ares may be customized according to customers requirements
Application

Applicable for power connection of coal cutter and similar equipment with rated voltage up to and including 1.9/3.3kv

Packing

We can according to customer requirement